Openings must be located more than 10 feet measured in any direction from an open combustion chamber or draft hood of another appliance located in the same room or space. - The amount of return air taken from any room or space must not exceed the flow rate of supply air delivered to that room or space. - Return air must not be taken from a closet, bathroom, toilet room, kitchen, garage, mechanical room, boiler room, furnace room, or unconditioned attic.

🎲 Try a Random Question  |  Total Questions in Quiz: 115  |  🧠 Study this quiz with Flashcards
This question is part of a full practice quiz:
TREC Home Inspector National Exam: HVAC — practice the complete quiz, review flashcards, or try a random question.


1. Openings must be located more than 10 feet measured in any direction from an open combustion chamber or draft hood of another appliance located in the same room or space. - The amount of return air taken from any room or space must not exceed the flow rate of supply air delivered to that room or space. - Return air must not be taken from a closet, bathroom, toilet room, kitchen, garage, mechanical room, boiler room, furnace room, or unconditioned attic.