1. Any portion of a masonry chimney located in the interior of the building (such as in an attic space) must have a clearance of at least ________ from any combustibles.

2. The _________ and every sleeping room should have at least one operable emergency escape and rescue opening that opens directly into a public street, public alley, yard or court.

3. The only type of fixture trap permitted is a(n) ___-trap.

4. T/F: Glazing in railings is considered a hazardous location.

5. T/F: The door between an attached garage and a dwelling unit should be of solid wood not less than 2 inches thick.

6. _____ clearance is required from windows that do not open.

7. T/F: In general, there should be no openings in the ductwork installed in a garage area.

8. Air-admittance valves are ________-activated.

9. If particleboard is used as wall sheathing, the grade mark with Type _____ or _____ should be stamped on it.

10. Foundation anchor bolts should extend at least ____ inches into masonry or concrete.

11. Glass block is considered ________.

12. All FVIR water tanks have components in common, including the ___________.

13. To prevent walls and floors from shifting under lateral loads, anchor bolts or ________ attached to the foundation are required.

14. T/F: It is acceptable for a service panel to be located inside a clothes closet.

15. T/F: Air-admittance valves are permitted to vent fixtures installed at island structures in kitchens.

16. There should be at least ____-inch gypsum board applied on the garage side to separate the garage from the residence and its attic space.

17. T/F: A standpipe can serve as an indirect waste receptor.

18. T/F: Glazing in storm doors is considered a hazardous location.

19. The TPR valve should be located in the upper 6 inches of a hot water tank, where the _______ water is located.

20. In high-wind installations, each composition roof shingle should be held by at least _______ nails or staples.

21. An open vent pipe that passes through a roof should extend at least _____ inches above the roof.

22. T/F: The opening to an attic space that has any mechanical equipment located in it should be a maximum of 20 inches by 20 inches.

23. T/F: Glass in bi-fold closet doors is considered a hazardous location.

24. The upper edge of a masonry chimney cleanout should be at least ____ inches below the lowest inlet opening.

25. Open electrical service conductors and multi-conductor cables that are not installed in a raceway or provided with an approved overall outer jacket should have a clearance of at least _____ feet from the sides of doors, porches, decks, stairs, ladders, fire escapes and balconies, and from the sides and bottoms of operable windows.