Home > General Studies (Hindi) > Quizzes > Plumbing: Sanitary Drainage
Plumbing: Sanitary Drainage
Fast practice, instant feedback. Timer auto-submits when time’s up.
Avg score: 85% Most missed: “A sewage ejector must”
A sanitary drainage system removes sewage and wastewater from buildings to disposal systems, typically using gravity-driven, properly vented piping (PVC, cast iron). It includes fixtures, traps, and pipes (soil/waste) that must maintain a minimum slope (usually 2%) to prevent blockages, ensuring efficient flow to municipal sewers or septic tanks.  Key Components of a Sanitary Drainage System Drainage Piping: Includes branch lines, waste pipes (liquid waste only), and soil pipes (human excreta). Traps:Installed at every fixture to prevent odor and gas from entering the building. Vents:... Show more
Plumbing: Sanitary Drainage
Time left 00:00
25 Questions

1. Vitrified clay tile pipe can be used for a building drain.
2. Manholes must be installed on sewer pipes greater in diameter than
3. A local vent
4. Purple primer is no longer used on PVC solvent weld joints.
5. A cleanout must be installed at every change of direction in a building drain.
6. One bathroom group, one laundry tray, one kitchen sink, and a half-bath consisting of a water closet and a lavatory have a drainage load of
7. Which fittings can be used directly below a water closet connection?
8. Approved methods for joining cast-iron pipe include
9. Bituminous fiber pipe can only be used for a building sewer.
10. In a food service establishment, exposed drainage piping can be installed
11. Concrete pipe is acceptable for an underground building drain.
12. Glass pipe can be joined by heating and melting (welding) the glass together.
13. A backwater valve must be full-opening.
14. A bathroom group has a DFU value of
15. Lead pipe can be used for chemical waste.
16. A backwater valve is installed if the elevation of the nearest manhole is above the elevation of the flood-level rim of any fixture.
17. Every soil stack requires a cleanout at its base.
18. Which of these are permitted in a public sewer without treatment?
19. A sewage ejector must
20. Schedule 40 PVC pipe can be threaded to make connections to other pipe materials.
21. In building sewers that are 8 inches or larger, a manhole is required only at changes of direction.
22. A wye can be used to convey waste in
23. Cleanouts must be
24. ABS solvent welding is a one-step process.
25. Most flat-bottomed fixtures have a DFU value of