Home > Plumbing Certification > Quizzes > Plumbing: Indirect And Special Wastes
Plumbing: Indirect And Special Wastes
Fast practice, instant feedback. Timer auto-submits when time’s up.
Avg score: 87% Most missed: “All sterilization equipment”
Indirect waste plumbing utilizes an intentional, non-sealed air gap or break between equipment drain pipes and the sanitary drainage system to prevent backflow contamination. Primarily required for food handling, medical, or specialized equipment, it ensures wastewater cannot contaminate potable water or clean areas. Key components include air gaps, air breaks, and specialized receptors.  Indirect Waste Principles Definition: A drain pipe that does not connect directly to the drainage system, instead discharging into a waste receptor (like a floor sink) through an air gap. Purpose:... Show more
Plumbing: Indirect And Special Wastes
Time left 00:00
25 Questions

1. Indirect waste pipes that exceed _____ feet in developed length must be trapped.
2. If an indirect waste is long enough to require a vent, the vent
3. The drain from a swimming pool filter backwash can be drained
4. An air-conditioning condensate drain can connect to a lavatory tailpiece.
5. How can a steam vent be drained to a sanitary drainage system?
6. If draining to a sanitary drain, pool deck drains must pass through an air gap.
7. A vent on an indirect waste is required when the developed length of the indirect waste pipe is _____ feet or longer.
8. Commercial dishwashing machines may be directly connected to the sanitary drainage system
9. The connection created when the discharge hose of an automatic washing machine is inserted into a standpipe is called
10. Chemical drainage and vent systems must be separate from the building drain and vent system.
11. The materials used for standard drainage systems are high enough quality for an indirect waste.
12. A drinking fountain may be directly or indirectly connected to the sanitary drainage system.
13. Standpipes
14. Which fixture must be drained indirectly?
15. All of the drains in a combination fixture that is used for food preparation must be individually trapped.
16. If the discharge of nonpotable water from a boiler drains through an indirect waste, an air gap must be used.
17. Condensate drains from refrigeration equipment must be indirectly drained, but may be drained with an air break.
18. When an air break is specified, an air gap is acceptable.
19. Corrosive waste can be discharged into a plumbing system if
20. All sterilization equipment
21. In an indirect waste, the distance between the outlet of the indirect waste pipe and the flood-level rim of the receptor must be
22. The drain hose for a domestic dishwasher
23. The purpose of an air gap is
24. An indirect drain from a refrigeration coil can be no longer than
25. Indirect waste pipe materials can be