Home > Plumbing Certification > Quizzes > Plumbing: Sanitary Drainage
Plumbing: Sanitary Drainage
Fast practice, instant feedback. Timer auto-submits when time’s up.
Avg score: 85% Most missed: “A sewage ejector must”
A sanitary drainage system removes sewage and wastewater from buildings to disposal systems, typically using gravity-driven, properly vented piping (PVC, cast iron). It includes fixtures, traps, and pipes (soil/waste) that must maintain a minimum slope (usually 2%) to prevent blockages, ensuring efficient flow to municipal sewers or septic tanks.  Key Components of a Sanitary Drainage System Drainage Piping: Includes branch lines, waste pipes (liquid waste only), and soil pipes (human excreta). Traps:Installed at every fixture to prevent odor and gas from entering the building. Vents:... Show more
Plumbing: Sanitary Drainage
Time left 00:00
25 Questions

1. Concrete pipe is acceptable for an underground building drain.
2. Waste that can enter a building subdrain can be the discharge from
3. Most flat-bottomed fixtures have a DFU value of
4. Approved methods for joining concrete pipe are
5. One bathroom group, one laundry tray, one kitchen sink, and a half-bath consisting of a water closet and a lavatory have a drainage load of
6. A local vent
7. In a food service establishment, exposed drainage piping can be installed
8. When is it allowable for sewage to be disposed of without treatment?
9. A backwater valve must be full-opening.
10. A sewage ejector must
11. Bituminous fiber pipe can only be used for a building sewer.
12. A backwater valve is installed if the elevation of the nearest manhole is above the elevation of the flood-level rim of any fixture.
13. A tee wye can be used to convey waste in a horizontal to horizontal pattern.
14. Which fittings can be used directly below a water closet connection?
15. Schedule 40 PVC pipe can be threaded to make connections to other pipe materials.
16. A bathroom group has a DFU value of
17. Vitrified clay tile pipe can be used for a building drain.
18. Which of these are permitted in a public sewer without treatment?
19. Every soil stack requires a cleanout at its base.
20. Approved methods for joining cast-iron pipe include
21. Glass pipe can be joined by heating and melting (welding) the glass together.
22. Lead pipe can be used for chemical waste.
23. Solvent welded PVC pipe can be used for a building sewer.
24. Manholes must be installed on sewer pipes greater in diameter than
25. In building sewers that are 8 inches or larger, a manhole is required only at changes of direction.