NYC Master Electrician Exam Questions
Fast practice, instant feedback. Timer auto-submits when time’s up.
Avg score: 68% Most missed: “—— Cartridge fuses of the renewable type shall be permitted to be used only for …”
NYC Master Electrician Exam Questions
Time left 00:00
25 Questions

1. Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____Amps shall be permitted to be supplied through a suitable attachment plug cap and hard service cable or cord .

2. A limited care facility is an area used on a ____hour basis for the housing of four or more persons who are incapable of self-preservation because of age, physical limitation due to accident or illness, or mental limitations, mental illness, or chemical dependency.

3. Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____ duplex receptacles

4. Type ____ is multiconductor cable identified for use as underground service entrance cable.

5. Outdoor electrical vehicle charging sites, unless specifically listed for the purpose and location, the coupling means of the electric vehicle supply equipment shall be stored or located at a height of not less than ____ inches and not more than ____ft.

6. In a healthcare facility, the maximum internal current permitted to flow through a line isolated monitor,when any point of the isolated system is grounded, shall be ____ .

7. Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord.

8. Rigid metal conduit that is directly buried outdoors shall have at least ____inches of cover.

9. Which is not considered a power supply?

10. Transfer eguipment, including automatic transfer switches,shall be

11. Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or similar areas

12. For cord and plug connected electric vehicle supply equipment is used, the interrupting devices of a listed personnel protection system shall be provided and shall be located in the power supply cable not more than ____inches from the attachment plug.

13. When service disconnecting means is a power-operated switch or circuit breaker, it shall be able to be opened by hand in the event of a —— —— ——.

14. Infrared Lamps for commercial and industrial heating appliances shall have over-current protection not exceeding ____ Amps.

15. Service drops Installed over roof shall have a vertical clearance of ____ above the roof surface, and unless a lesser distance is permitted by and exceptions

16. Track lighting with outlets in a bathroom is not allowed because ?

17. Where cables or nonmetallic raceways are installed through bored holes in joist, rafters, or wood members, holes shall be bored so that the edge of the hole is not less than ____ from the nearest edge of the wood member.

18. Which flexible cable is allowed to be used for a Electric Vehicle Charging Station?

19. What is not listed on a motor disconnect switch?

20. What is the minimum height for a vertical overhead clearance for a service drop conductors over residential property and driveways with garage, not subject to truck traffic where the voltage does not exceed 300V.

21. The feeder conductor ampacity shall not be less than that of the service-entrance conductors with an ampacity of ____Amps or less

22. A fixed storage type water heater of 120 gallons or less shall be considered a continuous, load and the branch circuits conductors shall have an ampacity of ____ % of the nameplate current rating

23. The working space in front of the electric equipment shall not be less than ____ inches wide, or the width of the equipment, whichever is greater.

24. Overhead feeder conductors shall have a minimum ____feet vertical clearance over residential property and driveways, as well as those commercial areas not subject to truck traffic, where the voltage is limited to 300V to-ground.

25. A separation of at least ____ft shall be maintained between communication wires and cables on buildings and lighting conductors, where practicable.