Fire Protection & Detection
Fast practice, instant feedback. Timer auto-submits when time’s up.
Avg score: 62% Most missed: “Certain Systems Are Appropriate For Some Hazards - Conditions And Applications -…”
Fire Protection & Detection
Time left 00:00
25 Questions

1. Some Manufactures Recommend That A Full Discharge Test On Wet And Dry Chemical Systems Occur Every ______ Years.

2. A Manually Operated Initiation Device Found In An Enclosure That Transmits Alarm Signals To A Municipal Communications Center Is Known As A(N) ______ Fire Alarm Box.

3. Nfpa _____ - Standard For The Installation Of Standpipe And Hose System Is The Most Widely Known And Used Document Outlining Design And Installation Requirements For Standpipe And Hose Systems

4. An Independent Organization Recognized Throughout The World As A Leader In Fire And Safety Testing And Evaluation To Determine If Products Meet Certain Established Safety And Performance Standards Is The _______.

5. _______ Are The Most Versatile Audible Notification Appliances Available Due To Their Ability To Reproduce Many Different Sounds And Signal Sources.

6. Routine Maintenance Follow The Manufacturer's Guidelines But Conditions May Dictate The Need To Perform Maintenance After The Scheduled Time.

7. The ______ System Is A Fire Suppression System Where The Fire Sprinkler System Connects To The Standpipe System Riser That Supplies The Water For The Standpipe And Fire Sprinkler System.

8. The Use And Occupancy Of A Building Or Use And Occupancy Area Within A Building Is The Last Factor Used To Determine Any Installation Requirement.

9. By Establishing A Classification System - A Consistent And Uniform Set Of Guidelines Applies To The Design Of Automatic Fire Sprinkler Systems.

10. A Detectors Device That Provides Coverage Over A Wide Area Where The Sensing Element Is A Tube Or Wires Easily Run In Different Directions Is Known As A ______ Detector.

11. When Dealing With Flammable And Combustible Liquid Fires - Class _____ Foam Is One Of The Best Suppression Agents Available.

12. What Section Of 633 Are The Licensing Requirements Set Out For Fire Suppression Equipment?

13. Classification Of Automatic Fire Detectors Is By The Component Of A Fire Signature They Detect.

14. First Published In 1975 - Nfpa ______ Addressed The Residential Fire Problem By Placing Fire Sprinklers In The Areas Of A Home Where A Fire Would Most Likely Start.

15. Fire Inspectors Certified By The State Fire Marshal Office May Work In Any County In The State With Out Any Additional Certifications?

16. The _____ Standard Provides The Minimum Requirements For The Design - Installation - Maintenance - Inspection - And Testing Of Water Mist Systems But It Does Not Establish An Operational Measure Or Offer Specific Guidance On How The Design - Control Suppress - Or Extinguish A Fire.

17. Generally - Standpipes Are Required To Be Installed In Structures Where Occupied Levels Are More Than ______ Feet Above Or Below Fire Department Vehicle Access - Or In Single-level Buildings With A Large Footprint - Such As A Large Storage Warehouse.

18. An Engineered Device That Directs A Pressurized Stream Of Agent In A Particular Direction - At The Desired Density - And In A Specific Pattern To Cover The Hazard With The Agent Is Known As A _______.

19. When Repairing - Modifying Or Adding To An Existing System Nfpa 72 Specifies _____ Percent Testing Of Devices Directly Affected By The Changes

20. A(N) _____ Is A System Of Components And Devices That Provide A Manual Or Automatic Means To Activate Fire Alarm And Supervisory Signals.

21. The _____ Smoke Detector Is A Type Of Smoke Detector That Samples Air As It Moves Through The Air Distribution System Ductwork.

22. If Required By The Authority (Nfpa 1) - Or When A Building Reaches ____ Feet In Height Above The Lowest Level Of Fire Department Access (Ibc) - At Least One Temporary Or Permanent Standpipe Is Required.

23. ______ Covers The Design - Installation - Inspection - Testing And Maintenance Of Fixed - Semi-fixed Or Portable Low- - Medium- - And High Expansion Foam Fire-extinguishing Systems For Interior Or Exterior Hazards..

24. Hydrostatic Test And Air Test Requirements For Water-based Systems Have A Predetermined Pressure - Usually _______ Psi For 2 Hours.

25. A (N) ______ Fire Alarm System Uses The Power From The Municipal Fire Alarm Circuits To Supply Current To The Building Fire Alarm System.