Home > Construction Industry > Quizzes > Building & Construction Practice Test: Ventilation
Building & Construction Practice Test: Ventilation
Fast practice, instant feedback. Timer auto-submits when time’s up.
Avg score: 72% Most missed: “Removal of inside air and supply of fresh outside air in a closed room is known …”
Here are some basics of building ventilation: Natural ventilation: The flow of air between the inside and outside of a building. Natural ventilation can be caused by pressure differences from the wind or temperature differences. Mechanical ventilation: Uses fans installed in walls, windows, or air ducts to supply or exhaust air. Mechanical ventilation can reduce noise and air pollution. Hybrid ventilation: A combination of natural and mechanical ventilation systems. Hybrid ventilation uses sensors and controls to automatically switch between systems based on indoor and outdoor... Show more
Building & Construction Practice Test: Ventilation
Time left 00:00
25 Questions

1. In Winter, the outside air is cool and hence, the process of air conditioning involves filtering, preheating and _____________
2. The difference of temperature between the outside air and inside air tends to the deposition of moisture in the room surfaces known as ___________
3. __________________ are used to collect the valuable chemical or mineral dusts.
4. For comfortable working, the ___________ content should be limited to about 0.6% by volume.
5. In _____________ system, some mechanical arrangement is adopted to provide enough ventilation to the room.
6. The rate of amount of water vapour present to the amount it would have contained, had it been saturated, is known as the ___________ the temperature being same.
7. It is quite evident that the incoming air for ventilation should be ________ in summer and ________ in winter before it enters the room.
8. Combination system consist of supply system and __________ system.
9. The value of ______________ depends on type of activity, geographical conditions, age of occupants, etc.
10. For working a temperature of 21 degree Celsius, range of 30% to 70% of ____________ is desirable.
11. In Summer, the outside air is hot and hence the process of air conditioning involves filtering, dehumidification and _________
12. The ____________ of suitable type may be used to distribute air inside the room.
13. _____________ is the process by which the required amount of moisture is added in the air.
14. In summer, it is necessary to supply ___________ air inside the room before it enters the room.
15. In ______________ system, the partial vacuum is created inside of the room by exhausting the vitiated inside air by fans or blowers.
16. The term __________ is used to indicate the science of controlling air with respect to humidity, temperature, movement of air, bacteria content, etc.
17. The term _________ is used to mean the free passage of clean air in a structure.
18. The general temperature difference between inside and outside of a room is not more than ____________
19. __________________ is an index which combines the effect of air movement, humidity and temperature.
20. The maximum rate of air change is __________
21. ________________ is the process by which the required amount of moisture is taken out from the air.
22. The ________________ plays an important role in the comfort of persons affected by ventilation system.
23. The _________ are the substances which allow moisture to stay on their surfaces.
24. ________________ are made of sheet metal of suitable size and shape to convey the conditioned air.
25. Where people are working, there has to be ______________ to cause proper ventilation of the premises.