NEC 430 Motors and Controllers
Fast practice, instant feedback. Timer auto-submits when time’s up.
Avg score: 3% Most missed: “For general motor applications, separate motor overload protection shall be base…”
NEC Article 430 covers the installation of motors, motor circuits, and controllers, providing requirements for branch circuits, short-circuit/ground-fault protection, overload protection, and disconnecting means. It features 14 parts (430.1–430.120) designed for specialized motor inrush currents.  Key Components and Requirements Conductor Sizing: Branch circuit conductors must have an ampacity of at least 125% of the motor’s full-load current (FLC). Overload Protection: Motors must have protection against burnout due to overload, typically sized at 115%–125% of the motor’s nameplate... Show more
NEC 430 Motors and Controllers
Time left 00:00
25 Questions

1. An individual disconnecting means shall be provided for each motor controller and be located _____ from the controller location.
2. The maximum dual-element time-delay fuse branch-circuit protection for a single-phase motor is:
3. If a motor disconnecting means is a motor-circuit switch, it shall be rated in:
4. An individual disconnecting means shall be provided for each motor controller and be located _____ from the controller location.
5. For general motor applications, separate motor overload protection shall be based on:
6. A branch-circuit overcurrent device can serve as the disconnecting means for a stationary motor of:
7. For general motor applications, the full-load current values in NEC Tables 430.247 through 430.250 are used to determine:
8. For stationary motors of 2 hp or less and 300V or less on AC circuits, an AC-rated general-use snap switch may be used where the motor full-load current is not more than _____ of the switch rating.
9. The maximum instantaneous-trip breaker branch-circuit protection for a single-phase motor is:
10. A branch-circuit overcurrent device can serve as the disconnecting means for a stationary motor of:
11. If a motor disconnecting means is a motor-circuit switch, it shall be rated in:
12. Motor control circuits shall be arranged so they are disconnected from all sources of supply when the disconnecting means is in the _____ position.
13. Motor branch-circuit short-circuit/ground-fault protection and overload protection:
14. Conductors supplying several motors shall have an ampacity of at least:
15. A motor with a marked temperature rise of 40°C or less shall have an overload device rated at no more than:
16. The maximum instantaneous-trip breaker branch-circuit protection for a single-phase motor is:
17. Short-circuit and ground-fault protection for a motor branch circuit must be capable of carrying the motor’s:
18. Short-circuit and ground-fault protection for a motor branch circuit must be capable of carrying the motor’s:
19. The maximum overcurrent protective device for 14 AWG motor control wiring that extends beyond the enclosure is:
20. A motor with a marked temperature rise of 40°C or less shall have an overload device rated at no more than:
21. Motor control circuits shall be arranged so they are disconnected from all sources of supply when the disconnecting means is in the _____ position.
22. Branch-circuit conductors supplying a single continuous-duty motor shall have an ampacity of at least:
23. If the motor control circuit conductor is based on Table 310.17 and does not extend beyond the enclosure, overcurrent protection shall not exceed:
24. Conductors supplying several motors shall have an ampacity of at least:
25. If the motor control circuit conductor is based on Table 310.17 and does not extend beyond the enclosure, overcurrent protection shall not exceed: