NEC 430 Motors and Controllers 2
Fast practice, instant feedback. Timer auto-submits when time’s up.
Avg score: 67% Most missed: “For general motor applications, the full-load current values in NEC Tables 430.2…”
NEC Article 430 covers requirements for motor circuits, controllers, and protection, primarily focusing on sizing conductors and overcurrent devices (OCPD) to handle high inrush currents, typically requiring branch circuit conductors sized at 125% of the motor full-load current (FLC). Key requirements include separate short-circuit/ground-fault protection (Part IV) and overload protection (Part III).  Key Components of NEC Article 430: Motor Conductor Sizing (430.22): Conductors supplying a single motor must have an ampacity not less than 125% of the motor’s full-load current (FLC)... Show more
NEC 430 Motors and Controllers 2
Time left 00:00
25 Questions

1. What is the full-load current of a three-phase, 230V, 10 hp motor?
2. A separate overload device protecting a continuous-duty motor over 1 hp with service factor 1.15 or greater shall trip at no more than:
3. The maximum overcurrent protective device for 14 AWG motor control wiring that extends beyond the enclosure is:
4. Motor control circuits shall be arranged so they are disconnected from all sources of supply when the disconnecting means is in the _____ position.
5. What is the full-load current of a three-phase, 230V, 10 hp motor?
6. Motor control circuits shall be arranged so they are disconnected from all sources of supply when the disconnecting means is in the _____ position.
7. Motor control circuit conductors extending beyond the motor control equipment enclosure shall have short-circuit and ground-fault protection not greater than:
8. For stationary motors of 2 hp or less and 300V or less on AC circuits, an AC-rated general-use snap switch may be used where the motor full-load current is not more than _____ of the switch rating.
9. For stationary motors of 2 hp or less and 300V or less on AC circuits, an AC-rated general-use snap switch may be used where the motor full-load current is not more than _____ of the switch rating.
10. An individual disconnecting means shall be provided for each motor controller and be located _____ from the controller location.
11. The maximum dual-element time-delay fuse branch-circuit protection for a single-phase motor is:
12. Overload devices are intended to protect against:
13. A branch-circuit overcurrent device can serve as the disconnecting means for a stationary motor of:
14. A 14 AWG motor control circuit tapped from the load side of the motor short-circuit protective device, requiring only short-circuit protection and not extending beyond the enclosure, has a maximum overcurrent protection of:
15. For general motor applications, separate motor overload protection shall be based on:
16. A motor with a marked temperature rise of 40°C or less shall have an overload device rated at no more than:
17. If a motor disconnecting means is a motor-circuit switch, it shall be rated in:
18. A _____ rated in amperes is permitted as a controller for all motors.
19. The maximum instantaneous-trip breaker branch-circuit protection for a single-phase motor is:
20. Branch-circuit conductors supplying a single continuous-duty motor shall have an ampacity of at least:
21. Short-circuit and ground-fault protection for a motor branch circuit must be capable of carrying the motor’s:
22. Motor controllers shall have horsepower ratings at the application voltage that are _____ the horsepower rating of the motor.
23. The maximum overcurrent protective device for 14 AWG motor control wiring that extends beyond the enclosure is:
24. The maximum instantaneous-trip breaker branch-circuit protection for a single-phase motor is:
25. If the motor control circuit conductor is based on Table 310.17 and does not extend beyond the enclosure, overcurrent protection shall not exceed: